Atmosphere Furnaces · Standard configuration

Vertical Atmosphere Furnace

Vertical Atmosphere Furnace is a HuanYu atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Published configuration references include Up to 1000 °C and Controlled atmosphere. Final selection depends on the material, workload, process window and selected configuration.

Direct definition

Vertical Atmosphere Furnace is specified around a defined material process.

Vertical Atmosphere Furnace is a atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. The published record should be reviewed against the required material, temperature, atmosphere, pressure, workload and acceptance criteria.

Published model

Standard configuration is documented with temperature range: Up to 1000 °C; atmosphere / pressure: Controlled atmosphere.

Technical overview

Designed around the complete thermal process.

Vertical Atmosphere Furnace is a HuanYu atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Published configuration references include Up to 1000 °C and Controlled atmosphere. Final selection depends on the material, workload, process window and selected configuration.

01

protected-gas sintering

02

reduction

03

annealing

04

atmosphere heat treatment

Key technical facts

  • Temperature reference: Up to 1000 °C
  • Environment reference: Controlled atmosphere
  • Vertical atmosphere furnaces are widely used in laboratories such as coal, electricity, metallurgy, and chemical industries, as well as in laboratory analysis and industrial heat treatment in universities and colleges. Technical features: 1. Single-chip microcomputer control, digital tube display, film button selection, easy to operate. 2. Automatic temperature reading, temperature control, constant temperature, control time, the results need to be manually calculated, the test data can not be stored. 3. A test can determine the ash or volatile content of a batch of coal samples. 4. With temperature control, the optional module can be used to facilitate the user's inspection burning, or to control the temperature and time according to the user's wishes. 5. Using a new lightweight fiber muffle furnace, the structure is novel, the appearance is beautiful, the heating is fast, the furnace has excellent constant temperature performance, and it is of course a choice to replace the old muffle furnace and the muffle furnace. 6. With break-double protection, over-temper protection, and thermoelectric dipole anti-protection technical parameters: 1. Temperature measurement range 0 ℃ ~ 1000 ℃ 2. Temperature measurement resolution 1 ℃ 3. Temperature control accuracy ± 5 ℃ 4. Control time 0 ~ 5999min 5. Timing resolution 1min 6. Timing accuracy 30s/24h

Technical parameters

Published configuration data.

Temperature rangeUp to 1000 °C
Atmosphere / pressureControlled atmosphere

Product details

Technical description from the published product record

Vertical atmosphere furnaces are widely used in laboratories such as coal, electricity, metallurgy, and chemical industries, as well as in laboratory analysis and industrial heat treatment in universities and colleges. Technical features: 1. Single-chip microcomputer control, digital tube display, film button selection, easy to operate. 2. Automatic temperature reading, temperature control, constant temperature, control time, the results need to be manually calculated, the test data can not be stored. 3. A test can determine the ash or volatile content of a batch of coal samples. 4. With temperature control, the optional module can be used to facilitate the user's inspection burning, or to control the temperature and time according to the user's wishes. 5. Using a new lightweight fiber muffle furnace, the structure is novel, the appearance is beautiful, the heating is fast, the furnace has excellent constant temperature performance, and it is of course a choice to replace the old muffle furnace and the muffle furnace. 6. With break-double protection, over-temper protection, and thermoelectric dipole anti-protection technical parameters: 1. Temperature measurement range 0 ℃ ~ 1000 ℃ 2. Temperature measurement resolution 1 ℃ 3. Temperature control accuracy ± 5 ℃ 4. Control time 0 ~ 5999min 5. Timing resolution 1min 6. Timing accuracy 30s/24h

Standard configuration

Included scope.

  • Confirm the included scope for the selected configuration.

Optional configuration

Available options.

  • Review tooling, controls, cooling and gas options with HuanYu.

Technical reading

Related guides and articles.

Use these pages to clarify the process window before requesting a configuration.

Vacuum Furnace Guide: Types, Uses and Selection Questions

Related equipment

Continue exploring this family.

Compare neighboring HuanYu configurations before you send the inquiry.

Horizontal Atmosphere Furnace

atmosphere furnaces

Horizontal Atmosphere Furnace

Horizontal Atmosphere Furnace is a HuanYu atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Published configuration references include Configuration specific and Controlled atmosphere. Final selection depends on the material, workload, process window and selected configuration.

TemperatureConfiguration specificConfigurations1

One published configuration

View equipment
Box Atmosphere Furnace

atmosphere furnaces

Box Atmosphere Furnace

Box Atmosphere Furnace is a HuanYu atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Published configuration references include 1100 / 1400 / 1600 / 1800 °C configurations and Controlled atmosphere. Final selection depends on the material, workload, process window and selected configuration.

Temperature1100 / 1400 / 1600 / 1800 °C configurationsConfigurations1

One published configuration

View equipment
Pit Atmosphere Furnace

atmosphere furnaces

Pit Atmosphere Furnace

Pit Atmosphere Furnace is a HuanYu atmosphere furnaces system for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Published configuration references include 1100 / 1400 / 1600 / 1700 °C configurations and Vacuum / controlled atmosphere. Final selection depends on the material, workload, process window and selected configuration.

Temperature1100 / 1400 / 1600 / 1700 °C configurationsConfigurations1

One published configuration

View equipment

Product FAQ

Questions to answer before requesting a configuration.

What is the Vertical Atmosphere Furnace used for?

Vertical Atmosphere Furnace is presented for protected-gas sintering, reduction, annealing, atmosphere heat treatment. Final process fit depends on the material, workload and operating environment.

What information should I provide for a technical recommendation?

Provide the material, part or sample dimensions, target temperature, atmosphere or vacuum level, batch size, process time, cooling preference and tooling requirements.

Can the equipment configuration be customized?

HuanYu can review chamber size, heating system, atmosphere, vacuum train, controls, cooling, tooling and safety interlocks before preparing a technical proposal.

Request a configuration

Turn product research into a technical conversation.

The more process context you share, the more useful our first reply can be.

No account is required. The form prepares an email in your default mail client.