Molybdenum & Tungsten Wire Furnace: Felt or Metal Shields
One chamber ships with two hot-zone builds — a graphite heater with graphite felt, or a tungsten element inside tungsten-molybdenum metal radiation shields — and that single choice decides yield, because above 1,600 °C residual moisture shuttles carbon into molybdenum, so the wire measures right and then breaks on the coiler. The published platform runs 2000–2300 °C in three chambers from Φ80 to Φ200 mm bore at 24, 45 and 65 kW, and power tracks hot-zone wall area rather than volume: 597 down to 296 kW/m², six to eleven times a 1,300 °C hot zone. Never mix a tungsten heater with graphite felt — the heater and the insulation are a matched pair. Pressure rise is only usable once it is converted to Pa·m³/h, so the RFQ should ask for the datasheet, the ISO 9001 certificate and the pressure-rise rate together.